About Me
With a background in Technical Medicine, Lennart's main passion lies within translational research of novel technologies into clinical practice. His research interests lie within the measurement and simulation of vascular biomechanics, with a special interest in patient-specific computational fluid dynamics modeling and ultrasound measurement of 2D-3D blood flow velocities.
Expertise
Medicine & Life Sciences
# Aneurysm
# Blood Pressure
# Hemodynamics
# Hydrodynamics
# Kidney
# Pressure
# Renal Artery Obstruction
# Stents
Organisations
Publications
Recent
Bouwmeester, T. A.
, van de Velde, L., Galenkamp, H., Postema, P. G.
, Westerhof, B. E., van den Born, B. J. H., & Collard, D. (2022).
Association between the reflection magnitude and blood pressure in a multiethnic cohort: the Healthy Life in an Urban Setting study.
Journal of hypertension,
40(11), 2263-2270.
https://doi.org/10.1097/HJH.0000000000003256
Van De Velde, L., Collard, D., Verberne, H., Lamers, A., Zijlstra, I., Vogt, L., & van den Born, B. J. (2022).
HERA3 study: Can pressure-flow measurements and computational flow simulations guide us when to treat renal artery stenosis?
Journal of hypertension,
40(Suppl 1), e247.
https://doi.org/10.1097/01.hjh.0000838012.61592.06
Bouwmeester, T.
, Van De Velde, L., Galenkamp, H., Postema, P. G.
, Westerhof, B. E., van den Born, B. J. H., & Collard, D. (2022).
Association between the reflection magnitude and blood-pressure in a multi-ethnic cohort: The helius study.
Journal of hypertension,
40(Suppl 1), e235.
https://doi.org/10.1097/01.hjh.0000837888.16505.66
van de Velde, L.
, Groot Jebbink, E., Zambrano, B. A.
, Versluis, M., Tessarek, J.
, & Reijnen, M. M. P. J. (2022).
The Supera Interwoven Nitinol Stent as a Flow Diverting Device in Popliteal Aneurysms.
CardioVascular and Interventional Radiology,
45, 858-866.
https://doi.org/10.1007/s00270-022-03118-x
Holewijn, S., Vermeulen, J. J. M.
, van Helvert, M.
, van de Velde, L.
, & Reijnen, M. M. P. J. (2022).
Validation of Central Pressure Estimation in Patients with an Aortic Aneurysm Before and After Endovascular Repair.
Cardiovascular engineering and technology,
13, 265-278.
https://doi.org/10.1007/s13239-021-00574-3
Chong, A.
, Mirgolbabaee, H., Sun, Z.
, Velde, L. V. D., Jansen, S., Doyle, B.
, Versluis, M.
, Reijnen, M. M. P. J.
, & Jebbink, E. G. (2021).
Hemodynamic Comparison of Stent-Grafts for the Treatment of Aortoiliac Occlusive Disease.
Journal of Endovascular Therapy,
28(4), 623-635.
https://doi.org/10.1177/15266028211016431
Engelhard, S.
, van de Velde, L.
, Jebbink, E. G.
, Reijnen, M. M. P. J.
, Versluis, M.
, Jain, K., Westenberg, J., & Zeebregts, C. J. (2021).
Blood Flow Quantification in Peripheral Arterial Disease: Emerging Diagnostic Techniques in Vascular Surgery.
Surgical technology international,
38, 294-304. [1410].
https://doi.org/10.52198/21.sti.38.cv1410
Holewijn, S., Vermeulen, J. J. M.
, van Helvert, M.
, van de Velde, L.
, & Reijnen, M. M. P. J. (2021).
Changes in Noninvasive Arterial Stiffness and Central Blood Pressure After Endovascular Abdominal Aneurysm Repair.
Journal of Endovascular Therapy,
28(3), 434-441.
https://doi.org/10.1177/15266028211007460
Collard, D.
, van de Velde, L., Vogt, L., & van den Born, B. J. H. (2021).
Authors’ reply.
Journal of the American Society of Nephrology,
32(1), 257-258.
https://doi.org/10.1681/ASN.2020101478
UT Research Information System
Google Scholar Link
Affiliated Study Programmes
Master
Contact Details
Visiting Address
University of Twente
Faculty of Science and Technology
Technohal
(building no. 18), room 2386
Hallenweg 5
7522NH Enschede
The Netherlands
Mailing Address
University of Twente
Faculty of Science and Technology
Technohal
2386
P.O. Box 217
7500 AE Enschede
The Netherlands